English French Spanish
  • RaySert®

    Single-use injector, designed for small-incision cataract surgery

    raysertRayner Intraocular Lenses Limited (Rayner), the leading intraocular lens (IOL) pioneer has introduced *RaySert®, a small-incision IOL injector system. With a 1.8-mm diameter external tip, RaySert® enables surgeons to insert an IOL through a sub-2.5-mm incision, reducing surgically induced astigmatism.

    Read More
  • Rayacryl®

    Injectable IOL Biomaterial

    All Rayner injectable lenses are manufactured from Rayacryl®, Rayner’s own proprietary hydrophilic acrylic co-polymer of 2-hydroxy ethyl methacrylate (HEMA) and methyl methacrylate (MMA) with ethylene glycol dimethacrylate (EGDMA) as cross-linking agent.

    silicone-oil

    Rayacryl® hydrophilic acrylic 5% silicone oil adherence

    acrysof

    Acrysof® hydrophobic acrylic 35% adherence

    Read More
  • Square Edge

    Reducing PCO

    square_edge

    The Amon-Apple Enhanced Square Edge is a unique Rayner design (patent pending) which reduces Posterior Capsular Opacification (PCO) by creating an insurmountable physical barrier to cell migration. Photo is courtesy of David J Apple MD, an SEM study of the fine surface finish on the haptic-optic junction of a Rayacryl® lens with the new edge.

    Read More
  • AVH

    Anti-Vaulting Haptic Technology

    Only Rayner injectable IOLs incorporate AVH Technology® to give unsurpassed clinical results.

    lens10_5mm lens10mm lens9_5mm
    Read More

Single-use injector, designed for small-incision cataract surgery

raysertRayner Intraocular Lenses Limited (Rayner), the leading intraocular lens (IOL) pioneer has introduced *RaySert®, a small-incision IOL injector system. With a 1.8-mm diameter external tip, RaySert® enables surgeons to insert an IOL through a sub-2.5-mm incision, reducing surgically induced astigmatism.

Read more: RaySert®

Category: Technology

Injectable IOL Biomaterial

All Rayner injectable lenses are manufactured from Rayacryl®, Rayner’s own proprietary hydrophilic acrylic co-polymer of 2-hydroxy ethyl methacrylate (HEMA) and methyl methacrylate (MMA) with ethylene glycol dimethacrylate (EGDMA) as cross-linking agent.

silicone-oil

Rayacryl® hydrophilic acrylic 5% silicone oil adherence

acrysof

Acrysof® hydrophobic acrylic 35% adherence

Read more: Rayacryl®

Category: Technology

Anti-Vaulting Haptic Technology

Only Rayner injectable IOLs incorporate AVH Technology® to give unsurpassed clinical results.

lens10_5mm lens10mm lens9_5mm

Read more: AVH

Category: Technology

Reducing PCO

square_edge

The Amon-Apple Enhanced Square Edge is a unique Rayner design (patent pending) which reduces Posterior Capsular Opacification (PCO) by creating an insurmountable physical barrier to cell migration. Photo is courtesy of David J Apple MD, an SEM study of the fine surface finish on the haptic-optic junction of a Rayacryl® lens with the new edge.

Read more: Square Edge

Category: Technology

Rayner IOL Extras

Rayner Injector Loading Video :: I-MED Surgical

Watch the Rayner Injector Loading Video

Rayner Aspheric IOL :: I-MED Surgical

Read more about the Rayner Aspheric IOLs

Rayacryl IOL Material :: I-MED Surgical

Read more about the Rayacryl® IOL Material

Rayner Aspheric IOL :: I-MED Surgical

Read more about the Rayner Aspheric IOLs

Silicone OIL :: I-MED Surgical

Read more about Silicone Oil

Enhanced Square Edge :: I-MED Surgical

Read more about the Enhanced Square Edge

Rayner T-flex toric IOL :: I-MED Surgical

Read more about the Rayner T-flex® toric IOL

I-Drop Extras

Dry Eye Checklist :: I-MED Pharma

Do You Suffer From Dry Eye?

Syndrome de l'oeil sec :: I-MED Pharma

Souffrez-vous du syndrome de l'oeil sec?

I-Drop<sup>®</sup> Technical Information :: I-MED Pharma

Read more about the I-Drop®