  • RaySert®

    Single-use injector, designed for small-incision cataract surgery

    raysertRayner Intraocular Lenses Limited (Rayner), the leading intraocular lens (IOL) pioneer has introduced *RaySert®, a small-incision IOL injector system. With a 1.8-mm diameter external tip, RaySert® enables surgeons to insert an IOL through a sub-2.5-mm incision, reducing surgically induced astigmatism.

    Read More
  • Rayacryl®

    Injectable IOL Biomaterial

    All Rayner injectable lenses are manufactured from Rayacryl®, Rayner’s own proprietary hydrophilic acrylic co-polymer of 2-hydroxy ethyl methacrylate (HEMA) and methyl methacrylate (MMA) with ethylene glycol dimethacrylate (EGDMA) as cross-linking agent.

    silicone-oil

    Rayacryl® hydrophilic acrylic 5% silicone oil adherence

    acrysof

    Acrysof® hydrophobic acrylic 35% adherence

    Read More
  • Square Edge

    Reducing PCO

    square_edge

    The Amon-Apple Enhanced Square Edge is a unique Rayner design (patent pending) which reduces Posterior Capsular Opacification (PCO) by creating an insurmountable physical barrier to cell migration. Photo is courtesy of David J Apple MD, an SEM study of the fine surface finish on the haptic-optic junction of a Rayacryl® lens with the new edge.

    Read More
  • AVH

    Anti-Vaulting Haptic Technology

    Only Rayner injectable IOLs incorporate AVH Technology® to give unsurpassed clinical results.

    lens10_5mm lens10mm lens9_5mm
    Read More

Rayner T-flex® Aspheric Toric IOLs

t-flexHydrophilic Acrylic Injectable Aspheric Toric
IOLs with Amon-Apple Enhanced Square Edge

Rayner T-flex® Aspheric Toric IOLs (573T and 623T) are a superior alternative to toric IOLs with a restricted range of torus and offer a precise, superior alternative to incisional keratotomy and Limbal Relaxing Incisions (LRIs) for the treatment of pre-existing corneal astigmatism. With T-flex® Aspheric Toric IOLs, the torus (cylinder) is implemented on the anterior surface of the optic and the Amon-Apple Enhanced Square Edge on the posterior surface.

T-flex® Aspheric Toric IOLs are particularly useful for those cataract patients where incisional methods would provide inadequate astigmatic correction. The choice of a T-flex® Aspheric Toric IOL leads to more precise surgical results, especially for cases of severe astigmatism: patients with a history of corneal pathology, keratoconus with penetrating keratoplasty (corneal grafts) and patients with burns and corneal scarring.

Unlike plate-haptic and multipiece toric IOLs, T-flex® Aspheric Toric IOLs have inherent rotational stability. Superb visual outcomes are achieved because of the dependable absence of rotation in lenses designed with Rayner’s AVH Technology®. T-flex® Aspheric IOLs are also available in a far greater range of cylinder and sphere combinations than some other toric IOLs, which are made with only a limited range of cylindrical additions. T-flex® Aspheric Toric IOLs correct much higher astigmatism.

Rayner T-flex® Aspheric IOLs are currently manufactured as either model 573T or model 623T, having a 5.75mm optic or a 6.25mm optic respectively.

The model selection is made automatically by Rayner so that the largest possible diameter optic is supplied for any particular sphere / cylinder / injector nozzle combination.

Model 623T is designed for low and medium power lenses and is anatomically correct for the larger, myopic eye. Model 573T is designed for higher power lenses.

In addition to an excellent toric correction, T-flex® Aspheric Toric IOLs offer all the additional advantages of C-flex® and Superflex®:

  • AVH Technology® for perfect centration, anterior / posterior and torsional stability
  • Exceptional rotational stability
    – Accurate, predictable and sustainable visual outcome with superior astigmatic correction
  • Amon-Apple Enhanced Square Edge for reduced PCO
  • Manufactured from Rayacryl® hydrophilic acrylic co-polymer:
    – High biocompatibility
    – Low PCO
    – Optical purity – no vacuoles or glistenings
    – Low Silicone Oil adherence
    – Superb handling characteristics.
  • Good range of spherical and cylindrical correction available.

Physical parameters

  • Optic Body Diameter: 573T: 5.75mm 623T: 6.25mm
  • Overall Length: 573T: 12.00mm 623T: 12.50mm
  • Estimated SRK A-Constant: 118.0
  • Theoretical ACD: 4.97mm

Power Availability (573T and 623T)

Standard Power Range

  • Spheres: +6.0D to +30.0D in 0.5D increments
  • Cylinders: +1.0D to +6.0D in 0.5D increments

Alternative Toric powers also available within the range:

  • Spheres: -10.0D to +35.0D maximum (spherical equivalent) in 0.5D increments
  • Cylinders: +1.0D to +11.0D in 0.25D increments.

Presentation

The Rayner T-flex® Aspheric (573T and 623T) hydrophilic acrylic injectable Toric IOLs are supplied in 0.9% saline solution in a pouched blister pack, sterilised by moist heat and presented in a convenient, ready to use Lens Injection System Pack containing:

  • One T-flex® Aspheric injectable IOL
  • One Rayner Single Use Soft-Tipped Injector

The IOL axis of lowest dioptric power is defined by two diametrically-opposed lines, etched onto the IOL periphery, which must be correctly aligned, intraoperatively, with the axis of the highest power of the cornea

Rayner IOL Extras

Rayner Injector Loading Video :: I-MED Surgical

Watch the Rayner Injector Loading Video

Rayner Aspheric IOL :: I-MED Surgical

Read more about the Rayner Aspheric IOLs

Rayacryl IOL Material :: I-MED Surgical

Read more about the Rayacryl® IOL Material

Rayner Aspheric IOL :: I-MED Surgical

Read more about the Rayner Aspheric IOLs

Silicone OIL :: I-MED Surgical

Read more about Silicone Oil

Enhanced Square Edge :: I-MED Surgical

Read more about the Enhanced Square Edge

Rayner T-flex toric IOL :: I-MED Surgical

Read more about the Rayner T-flex® toric IOL

I-Drop Extras

Dry Eye Checklist :: I-MED Pharma

Do You Suffer From Dry Eye?

Syndrome de l'oeil sec :: I-MED Pharma

Souffrez-vous du syndrome de l'oeil sec?

I-Drop<sup>®</sup> Technical Information :: I-MED Pharma

Read more about the I-Drop®